Copyright HT ITALIA 2012 Release EN 2.00 - 09/05/2012 ENGLISH User manual
HT326 EN - 94.3.3. DC Current measurement CAUTION The maximum input for DC current is 10A. Do not attempt to measure higher currents to avoi
HT326 EN - 104.3.4. AC Current measurement CAUTION The maximum input for DC current is 10A. Do not attempt to measure higher currents to avo
HT326 EN - 114.3.5. Resistance measurement CAUTION Before taking resistance measurements on the circuit remove power from the circuit being t
HT326 EN - 124.3.6. Continuity test CAUTION Before taking resistance measurements on the circuit remove power from the circuit being tested a
HT326 EN - 134.3.7. Diode test CAUTION Before taking resistance measurements on the circuit remove power from the circuit being tested and di
HT326 EN - 144.3.8. Frequency and Duty Cycle measurement CAUTION The maximum input for AC voltage is 600V. Do not attempt to measure higher
HT326 EN - 154.3.9. Capacitance measurement CAUTION Before taking capacitance measurements in circuit remove power from the circuit being tes
HT326 EN - 165. MAINTENANCE CAUTION Only skilled technicians can open the instrument and replace batteries. Before removing batteries discon
HT326 EN - 176. TECHNICAL SPECIFICATIONS 6.1. TECHNICAL FEATURES Accuracy is indicated as [%reading + (number of digits*resolution)] at 23°C±5°C,
HT326 EN - 18Diode Test Feature Direct voltage Accuracy Max Open Circuit Voltage Overload protection 0 – 1.000V (0.5%rdg + 3dgt) 1.5V 600V DC/A
HT326 EN - 1Table of Contents: 1. SAFETY PRECAUTIONS AND PROCEDURES ... 21.1. Prelimina
HT326 EN - 196.1.1. Reference standards Safety: IEC/EN61010-1 Insulation: double insulation Pollution degree: 2 Overvoltage category: CAT III
HT326 EN - 207. SERVICE 7.1. WARRANTY CONDITIONS This instrument is guaranteed against material or production defects, in accordance with our gen
HT326 EN - 21. SAFETY PRECAUTIONS AND PROCEDURES This meter is in compliance with IEC/EN61010-1 guideline related to electronic measuring instrum
HT326 EN - 31.2. DURING USE Read the recommendations which follow and the instructions in this manual: CAUTION An improper use may damage th
HT326 EN - 42. GENERAL DESCRIPTION This meter performs the below listed measurements: DC Voltage AC sine wave Voltage DC Current AC si
HT326 EN - 54. OPERATING INSTRUCTIONS 4.1. INSTRUMENT - DESCRIPTION 4.1.1. Front panel CAPTION: 1. LCD display 2. HOLD Key 3. R Key 4. REL
HT326 EN - 64.2. DESCRIPTION OF FUNCTION KEYS 4.2.1. HOLD key By pressing HOLD key the measured value is frozen on the display where the symbol
HT326 EN - 74.3. MEASUREMENTS 4.3.1. DC Voltage measurement CAUTION The maximum input for DC voltage is 600V. Do not attempt to measure high
HT326 EN - 84.3.2. AC Voltage measurement CAUTION The maximum input for AC voltage is 600V. Do not attempt to measure higher voltages to avo