6. TECHNICAL SPECIFICATIONS
6.1. TECHNICAL FEATURES
The accuracy is indicated as [% of reading + number of digits]. It is referred to the
following environmental conditions: temperature 23°C ± 5°C, relative humidity < 70%.
DC voltage measurement
Range Resolution Accuracy Input impedance
Protection against
overloads
1.5 ÷ 600.0V
0.1V
±(0.8%rdg+1dgt) 10M
DC/AC 660V rms
AC voltage measurement with 2 test leads
Range Resolution
Accuracy
(40.0 ÷ 69.9Hz)
Input impedance
Protection against
overloads
1.5 ÷ 600.0V
0.1V
±(1.5%rdg+5dgt) 10M
DC/AC 660V rms
Crest factor max: 2
Frequency measurement with 2 test leads
Range Resolution Accuracy Protection against overloads
40.0 ÷ 69.9Hz
0.1Hz
±(0.5%rdg+1dgt)
DC/AC 660V rms
Minimum detectable input voltage: 1.6V
Crest factor max: 2
AC voltage measurement with 1 test lead (*)
Range Resolution Accuracy Input impedance
50 ÷ 600V
10V
±(20%rdg+2dgt) 1M
Minimum detectable input frequency: 40.0 ÷ 69.9Hz
Crest factor max: 2
(*) On standard conditions: instrument correctly gripped, standard shoes, standard floor, etc.
Frequency measurement with 1 test lead (*)
Range Resolution Accuracy Input impedance
40.0 ÷ 69.9Hz
0.1Hz
±(1.0%rdg+2dgt) 1M
Minimum detectable input voltage: 50V
Crest factor max: 2
(*) On standard conditions: instrument correctly gripped, standard shoes, standard floor, etc.
Phase sequence test and phase conformity test (*)
Range Input impedance Protection against overloads
100 ÷ 600V 1M
600V AC RMS
Crest factor max: 2
(*) On standard conditions: instrument correctly gripped, standard shoes, standard floor, etc.
Resistance measurement
Range Resolution Accuracy Max open voltage
Protection against
overloads
0 ÷ 1499
1
±(1.0%rdg+5dgt)
About 0.4V
DC
DC/AC 600V rms
one minute
Continuity test
Range Buzzer Max open voltage Protection against overloads
< 100 About 1.5V
DC DC/AC 600V rms