HT9022
EN - 41
5.7. POSITION “Ω ”: RESISTANCE AND CONTINUITY MEASUREMENT
WARNING
Before attempting any resistance measurement, remove power from the
circuit under test and discharge all capacitors, if present.
By positioning the selector switch to “Ω ”, the screen to the side
will appear.
Mod OK Fnz
> 60.0 kΩ
19/01-17:00:00
Fig. 13: resistance measurement
Insert the red cable into the input lead VΩ and the black cable into the input lead COM,
and connect the instrument as described in Fig. 13.
Press key F1 (Mod) to open the drop-down menu shown on the
screen to the side. At each subsequent pressure of key F1, the
cursor will scroll through the available items, as follows:
• Resistance: resistance measurement;
• Continuity: continuity measurement;
• Help: it displays the connection between instrument and
system;
• Esc: it closes the drop-down menu.
Mod OK Fnz
> 60.0 kΩ
19/01-17:00:00
Select the desired mode and press key F3 (OK) to confirm.
Resistance
Continuity
Help
Esc